An error occurred if the "Print" script was used.(6.0.3)

⇒This problem was corrected in Ver6.0.3.

It may be unable to communicate, if an address is changed in GPIB.(6.0.2)

⇒This problem was corrected in Ver6.0.2.

When it only received, there was a case where reception was impossible. (4.0.1)

⇒This problem was corrected.

If it performs by Windows Vista, I cannot save a settings file. ( - )

Please start SGTERM by "administrator authority" in Windows Vista. Refer to it here for details.

I cannot install a software in Windows Vista. (3.0.0)

Please use a Windows Vista compatible version (3.0.0 or more). Perform installation by "administrator authority." Refer to it here for details.

When the Excel instruction book which described the Print sentence was used, "CELL" was chosen in Mode of Excel Settings tab and the execution test was performed, the error occurred. (2.0.2)

The problem was in processing of the execution test at the time of using a Print sentence.

⇒This problem was corrected.

At the time of finishing of SGTERM, I get an error message "75 path/file access error." ( - )

This message is displayed when SGTERM is used by a general user. A message is not displayed when it is used by a user (an administrator, power user) with the authority more than a power user. Reading/writing of a list settings are automatically performed at the time of starting/end of SGTERM. However, since a general user cannot write that, a message is displayed.

When you perform list execution by a general user, please perform a list setup at every starting of SGTERM. When not performing list execution, you can use SGTERM usually.

At the time of starting of SGTERM, I get an error message which cannot be read. ( - )

This message is displayed when SGTERM is started by a general user. A message is not displayed when it is used by a user (an administrator, power user) with the authority more than a power user.

If the password is registered by the user with administrator authority, even if this message is displayed, you can click the "O.K." button and can use SGTERM. If you have not registered the password yet, please register it.

If USB connection of the two controllers is made with PC, one of the two's communication may not be able to be performed. (2.0.0)

The problem was in processing of USB.

⇒This problem was corrected so that both could do communication correctly.

At the time of starting of SGTERM, I get a run-time error and cannot operate it occasionally. ( - )

When the setting of the font of "Properties" of Windows desktop is "Large font", at the time of starting of SGTERM, an error occurred and did not operate. (It does not occurr, when the font is set as the usual size.)

⇒Please start SGTERM after setting the font to "Standard font" by "Properties" of Windows desktop.

The way of setting of "Properties" of Windows desktop Right-click on Windows desktop. Click "Properties" by the displayed menu. Then, "Properties" of Windows desktop is displayed.
Click "Appearance" tab and select the scheme not displayed as "(... large)" or "(... extra large)" on "Scheme" by the pull-down.
When the "OK" button is clicked, properties of Windows desktop is set.

I cannot display the screen of SGTERM in English. (1.1.0)

SGTERM can be displayed in English after Version 1.2.0.

When I click the "File - Open" menu, I get an error message telling me to "Open method failed. " occasionally. (1.2.0)

When the file which was going to be opened in "File-Open" menu was already opened and was updated, the error message "Open method failed." was displayed. (This error occurs only when the file already opened is going to be opened again.)

⇒This problem was corrected.

The error might occur at the time of reading of a setting file. (1.2.0)

 

When the capital letter and small letter of instruction file name or output result file name in the setting file differ from an actual file name, the error occurred. (Normally, this error is not occurred unless the capital letter of a file name and a small letter are changed after writing setting file.)

⇒This problem was corrected.

I cannot save the book name and sheet name of No.128 of the Output Settings screen at a setting file. (1.1.0)

One data of output result table was lacking at the time of writing of a setting file. (Since missing data is the 128th data, the error does not usually occurs.)

⇒This problem was corrected so that all output result table might be written in.

When the setting file was read after inputting the comma into the selected range in Excel settings tab or device name in device settings tab, the item containing a comma was not read correctly. (1.1.0)

When the setting file was read after inputting the comma into the selected range in Excel settings tab or device name in device settings tab, the item containing a comma was not read correctly. (In the case of selected range in Excel settings tab, this problem is occurred only within the case where two or more selection ranges are registered into one selection range input column. Usually, this problem is not occurred when registering one selection range into one selection range input column.)

⇒This problem was corrected so that the item which contains a comma by reading of a settingfile might also be read correctly.

While waiting for the time specified during program execution, when 24:00 were exceeded, I cannot wait correctly. (1.1.0)

While waiting for the time specified during program execution, when 24:00 were exceeded, it was not able to wait correctly. (It is occurred only when program execution crosses in two days (24:00 are exceeded).)

⇒This problem was corrected so that it could wait correctly even if it exceeded 24:00.

On the detailed setting window of RS232C, I cannot change a setup of EOF. (1.1.0)

On the detailed setting window of RS232C, a setup of EOF was not performed correctly. (It is a problem only when using EOF. Usually, it is OK in order not to use it.)

⇒This problem was corrected so that a setup of EOF might be performed correctly.

Functional Addition / Specification Change

(Corresponding Version)

  • Setting file (an extension is .sge) was related with SGTERM. (4.0.1)
  • It corresponded to license management of the software by the USB key. (4.0.0)
  • It corresponded to WindowsVista. (3.0.0)
  • The license management method of software was changed.
    You can use it for 30 days after software installation.
    To use 30 days after continuously, a key (password) to open the lock for license management needs to be registered.
    Please refer to "About the license of software.pdf" about a registration method. (2.0.1)
  • It corresponded to specification of the read wait time.
    (It became possible to specify an interval between transmission and reception.) (2.0.0)
  • It corresponded to specification of the reading end strings.
    (It became possible to repeat reception until it received the specific character string.) (2.0.0)
  • It corresponded to communication of binary data by RS232C. (2.0.0)
  • The Print sentence and the PrintSet sentence were added to the control in a script. (2.0.0)
  • When the icon of a device was double-clicked in device settings tab, the setting window of the device was displayed. (1.1.0)
  • The shortcut key was assigned to the button of step run window. (1.1.0)